What we do, and what we do not
We do not carry out EICRs (Electrical Installation Condition Reports) ourselves. An EICR is the inspection; what we do is the repair work that follows it. You can bring us a report from any inspector: it belongs to you, and you are not tied to the firm that wrote it for the repairs.
For a landlord, a home buyer or anyone who has been handed an unsatisfactory report, that is usually the part that matters: someone to read the observations, tell you plainly what each one means, and put them right.
What makes a report unsatisfactory
Each issue on the report carries a code. Under the current Wiring Regulations, two of them make the overall result unsatisfactory:
- C1: danger present. It needs making safe straight away.
- C2: potentially dangerous. Remedial work is required.
- C3 means improvement is recommended, and FI means further investigation is advised. Neither makes a report unsatisfactory on its own.
- On a report written before the 2026 amendment to the regulations, FI meant further investigation was required without delay, and it normally did make the result unsatisfactory. Check the date on yours.
EICR remedial work in Bristol: the repairs we do most
- Replacing an old fuse board (consumer unit) that has no RCD protection.
- Adding or upgrading the main earth bonding to gas and water pipework.
- Replacing damaged sockets, switches and light fittings.
- Remaking loose or overheated connections.
- Replacing a circuit where the cable itself has deteriorated.
- Swapping bathroom fittings that are not suitable for where they are installed.
How it works
- Send us the report: a photo of the observations pages on WhatsApp is enough to start.
- We go through it with you item by item and give you a clear estimate for the work.
- We carry out the repairs, worst first. Many remedial lists are cleared in a single visit.
- You receive the certificate for the work and written confirmation that it has been done.
For landlords
If the property is rented out in England, the remedial work on an unsatisfactory report must be completed within 28 days of the inspection, or sooner if the report says so. You then pass written confirmation to your tenant and the council.
We supply that confirmation with the certificate for the work. Government guidance accepts it as evidence the installation now meets the standard, so a second full inspection is not normally needed.
Getting an estimate
Every home is different, so we give you a clear estimate before any work starts, with no call-out charge for providing one. If anything changes once we begin, we agree it with you before carrying on.
Ready to get it booked in? Get an estimate for the remedial work or call Mark on 07973 782 821. Based in Downend, covering Bristol and the surrounding areas. No call-out charge for estimates, and no obligation.
Frequently asked questions
Do you carry out the EICR itself?
No. We do the repair work a report identifies and certify it. If you need the inspection, any registered inspector can carry it out, and the report is yours to bring to us afterwards.
Do I have to use the firm that did the inspection for the repairs?
No. The report belongs to you, and any qualified electrician can carry out the remedial work from it.
Will I need another EICR after the repairs?
Usually not. The certificate for the remedial work, together with the original report, shows the installation has been put right. A buyer, lender or letting agent can still ask for a fresh report if they choose to.
How long does remedial work take?
Many lists are cleared in one visit. A straightforward fuse board replacement takes about half a day; rewiring a circuit takes longer, and we tell you that before we start.