Unsatisfactory EICR? What Happens Next (Failed EICR Guide)

Unsatisfactory EICR? What it means, the most common failures, what the remedial work involves, the 28-day rule for landlords and how to get signed off.

An unsatisfactory EICR (Electrical Installation Condition Report) is what most people call a failed EICR. It means the inspector recorded at least one C1 (danger present) or C2 (potentially dangerous) observation, so the overall assessment on the report reads “unsatisfactory” instead of “satisfactory”. On a report written before the 2026 amendment to the Wiring Regulations, an FI (further investigation) observation normally had the same effect. Putting it right means fixing those specific faults, not gutting the house, and once the work is done and certified, your installation counts as satisfactory again.

We don’t carry out EICRs ourselves. We do the repair work a report identifies, and certify it. So if you’re holding an unsatisfactory EICR report wondering what happens next, take comfort: almost every report looks worse on paper than in real life. The observations pages tell you exactly what needs doing and how urgent each item is. Work through them, get the paperwork, and you’re done.

Got an unsatisfactory report? Get an estimate for the remedial work or call Mark on 07973 782 821 — based in Downend, covering Bristol and surrounding areas. No call-out charge for estimates, and no obligation.

Satisfactory or unsatisfactory: can you fail an EICR?

Yes, in the sense that the report ends with one of two overall verdicts: satisfactory or unsatisfactory. But an EICR is not a pass-or-fail exam with a score. The inspector grades each issue with an observation code, and under the current edition of the Wiring Regulations, BS 7671:2018+A4:2026, only two codes make the report unsatisfactory:

Code What it means Makes the EICR unsatisfactory?
C1 Danger present, risk of injury. Needs immediate action Yes
C2 Potentially dangerous. Remedial work required Yes
C3 Improvement recommended, but not dangerous No
FI Further investigation advised (older reports: required without delay) Not on a current report; yes on an older one

One C1 or C2 anywhere on the report is enough. On the other hand, a report with ten C3s and nothing else is still satisfactory: nobody fails simply for having an older installation.

FI is the code that depends on the age of the report. On a report written to the current edition it reads “further investigation is advised” and, like a C3, does not make the report unsatisfactory on its own. On a report written before the 2026 amendment it meant further investigation was required without delay, and it normally did make the result unsatisfactory. Both kinds of report will be around for years, so check the date on yours. We’ve broken down what each code looks like in a real house in EICR codes explained.

With a C1 the danger exists right now, so a responsible inspector will tell you on the day and, with your permission, make it safe before leaving, even if that means isolating one circuit at the fuse board (consumer unit) until it’s repaired.

The most common EICR failures

The same handful of faults turn up on unsatisfactory reports again and again. These are the ones we are most often asked to put right in Bristol homes:

  • No RCD protection where it’s needed. An RCD (residual current device) is the trip switch that cuts the power in a fault before it can hurt anyone. Older fuse boards often have none, and missing protection on sockets that could supply equipment outdoors, or on a bathroom circuit where supplementary bonding is also missing, is commonly coded C2.
  • Missing or undersized earth bonding. The main bonding connects your gas and water pipework to the earthing system. In older houses it is often absent, too thin, or disconnected during plumbing work.
  • Damaged sockets, switches and fittings. Cracked faceplates, scorch marks or anything that leaves live parts within reach.
  • Loose or overheated connections. Found at the fuse board or behind accessories, usually from age or from alterations that were never tested.
  • Deteriorated old wiring. Rubber- or fabric-insulated cable that has gone brittle with age.
  • Unsuitable fittings in bathrooms. Lights or fans without the right protection against moisture for where they’re installed.

Many of these are small jobs. The bigger ones are a fuse board with no RCD protection and wiring that has genuinely perished. Where a board has no RCD protection at all, replacing it is usually the sensible fix.

What to do after an unsatisfactory EICR, step by step

An unsatisfactory report doesn’t put you on any register, and for owner-occupiers there’s no legal clock ticking.

  1. Read the observations pages. Each fault is listed with its code and location. That list is effectively your job sheet.
  2. Get an estimate for the remedial work. Any qualified electrician can estimate the work from the report, not just the firm that inspected. Ask for it itemised against the observations.
  3. Fix the faults, worst first. C1s straight away, C2s as soon as practical. Have anything marked FI investigated as soon as you can, because it may be hiding a C1 or C2. C3s are optional, though some are quick to sort while an electrician is there.
  4. Get the paperwork. The electrician certifies the remedial work. More on that below.

What EICR remedial work involves

Every report is different, so the only way to know what yours needs is to have an electrician read it. These are the jobs that come up most often on Bristol reports, with what each one involves and what makes it bigger or smaller:

Typical remedial job What it involves What makes it bigger or smaller
Replace a damaged socket, switch or light fitting Isolating the circuit, swapping the accessory and testing it How many points are affected, and the condition of the cable behind them
Tighten or re-terminate loose connections Opening up the board or accessory, remaking the connection, testing Whether heat has damaged the cable or the equipment itself
Further investigation (FI) of a flagged circuit Tracing and testing the circuit to find the cause of a poor reading How easy the cable route is to reach and follow
Add or upgrade main earth bonding to gas and water Running a new earth cable from the fuse board to the pipework The distance between the two, and the route through the house
Fuse board (consumer unit) replacement to add RCD protection Fitting a new board, testing every circuit and certifying the work The number of circuits, and any faults the testing uncovers
Partial rewire of one or more failed circuits Replacing the cable on the affected circuits only How many circuits, and how much lifting of floors or chasing of walls is needed

In our experience many remedial lists are cleared in a single visit. The common larger item is an old fuse board with no RCD protection. A straightforward replacement takes about half a day, with the power off for two to four hours of it, and it is worth allowing the full day in case testing turns up a fault. You can see what’s involved in our guide to fuse board replacement in Bristol. A full rewire is the exception, usually only where very old rubber- or fabric-insulated wiring is found.

We give a clear estimate before any work starts. If opening something up reveals more than the report showed, we agree any change with you before carrying on. Our page on remedial work after an unsatisfactory EICR sets out how we work from a report, and for what the inspection itself covers, see our guide to EICRs in Bristol.

Unsatisfactory EICR on a rented property: the 28-day rule

If the property is rented out in England, the law sets a firm timetable. Under the Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020, a landlord whose report shows that remedial work is required must have it done within 28 days starting with the date of the inspection, or sooner if the report specifies a shorter period. The clock starts at the inspection, not on the day the report arrives.

From 30 November 2026 that duty covers remedial work only. For an inspection completed before that date, it also covers any further investigation the report required.

You then need written confirmation from a qualified person that the work is done, and you must give it, with a copy of the original report, to each tenant and the local council within 28 days of finishing. Councils can impose substantial civil penalties for a breach, so this is not a deadline to sit on. The full detail is in the government’s electrical safety guidance for landlords, and our plain-English summary is in landlord EICR rules.

Many remedial lists are a day’s work or less, but the 28 days run from the inspection and include getting the report, an estimate and a date, so start straight away.

Do you need a whole new EICR afterwards?

Usually not, and this catches people out. Once the remedial work is done, the electrician issues an Electrical Installation Certificate (EIC) or a Minor Electrical Installation Works Certificate (MEIWC), plus written confirmation that the work has been carried out and the electrical safety standards are now met. Government guidance accepts a satisfactory EICR, an EIC or a MEIWC as proof for landlords, so you shouldn’t need the whole inspection again. Keep the unsatisfactory report and the new certificate together: between them they show the installation is now satisfactory.

The exception is when a buyer, lender or letting agent insists on a fresh satisfactory EICR, which means a second inspection by a registered inspector.

When we carry out remedial work, the certificate and written confirmation are part of the job, not an extra.

Frequently asked questions

What happens if an EICR is unsatisfactory?

Nothing happens automatically. The report lists each fault with a code, and it stays unsatisfactory until the C1 and C2 items are dealt with and certified. Owner-occupiers can choose when to act, though C1 and C2 faults are genuine safety issues. Landlords in England must complete the remedial work within 28 days starting with the date of the inspection, and send written confirmation to the tenant and the council.

How long do you have to fix a C2 on an EICR?

For a rented property in England, 28 days starting with the date of the inspection, or sooner if the report says so. For your own home there is no legal deadline, but a C2 is potentially dangerous, so it should be put right as soon as practical. A C1 is different: danger is present now, and it should be made safe on the day.

Is it illegal to live in a house with a failed EICR?

No. For owner-occupiers there’s no law forcing you to act on an unsatisfactory report, though C1 and C2 faults are genuine safety issues and a C1 means danger is present right now. For rented homes it’s different: the landlord must complete the remedial work within 28 days of the inspection or risk a civil penalty from the council.

Does a C3 mean my EICR failed?

No. C3 means “improvement recommended” and does not make a report unsatisfactory on its own. It flags things that were acceptable when installed but wouldn’t meet BS 7671, the current Wiring Regulations, if fitted today. Landlords in particular mix this up, so we’ve compared the two codes in C2 vs C3 for landlords.

Do I have to use the electrician who did the inspection?

No. The report is yours, and any qualified electrician can estimate and do the remedial work from it. A second estimate is often worthwhile if the list looks longer than expected. The work needs a qualified electrician: all of it has to meet the Building Regulations and BS 7671, some of it (a fuse board replacement or a new circuit) is also notifiable, and for a rented property it must be done and confirmed in writing by a qualified person.

Ready to get those faults put right and certified? Send us your unsatisfactory EICR and get an estimate for the remedial work, or call Mark on 07973 782 821. Based in Downend, covering Bristol and surrounding areas — free estimates, no hidden extras, and all work certified to BS 7671.